Error 47

Error Message Displayed to user

  • E47
  • Start Up Error

Condition

Message sent by the motor controller when no current is detected while trying to run the belt motor.

Cause

  • Bad cables
  • Bad motor controller
  • Bad motor

Remedy

  • Check motor wiring / terminals.
  • Measure motor thermal switch connections to ensure switch is closed.
  • Measure motor phase resistance to ensure no open circuits.
  • Check MDB LED's to ensure properly powered and communicating - replace Motor Controller if faulty (100, 101,200, 400, 500, 501, 502).
  • Check PTC LED's. See Error 21.
  • Diagnose / replace MDB or PTC.