Calibrate Resistance Level
- Press and hold the Up
arrow and Down
arrow for 3 seconds. - Navigate in the Toolbox menu to
DIAGNOSTICS with the Down
arrow. - Press the GO/Enter key to enter DIAGNOSTICS.
- Push the resistance lever forwards to the highest resistance level.
- Press and hold the Up
arrow for three seconds until the BRAKE VALUE section
blinks. The upper value is stored. - Pull the resistance lever backwards to the lowest resistance level.
- Press and hold the Down
arrow for three seconds until the BRAKE VALUE section
blinks. The lower value is stored. - Press the GO/Enter key to go BACK to the toolbox menu.
- Press the Down
arrow to select EXIT in the setup menu. - Press the GO/Enter key to exit Toolbox.
Diagnostics menu
| ARC TRAINER | Software revision number. |
| PRESSURE/TEMP |
Pressure: Displays Barometric pressure in HPA (hectopascal). Temperature : Displays local temperature in degrees Celsius. |
| BRAKE VALUE | Displays brake position value. Range is P1 to P10. |
| BATTERY | Displays battery level from 0 to 100% in 10% increments. LOW BATTERY screen will be displayed at 10%. |