System Settings
Warning: Calibration and adjustment settings for
technicians only.
Usage
Displays the number of hours in which the indoor cycle has been in use.
Firmware
Displays firmware version built in components.
Brake Calibration
The brake must be calibrated if the displayed level of resistance does not reach 0% or 100% at the end positions or an exclamation mark (!) is shown instead of the level as a % on the display.
Important: Follow the step by step directions
carefully as prompted on the display.
- If the values lie outside a certain range, the calibration may fail and a red screen will appear.
- Reattempt the calibration and make sure you follow the instructions carefully.
- If the calibration fails again, the resistance system must be adjusted mechanically. Please refer to technical service in this case.