Anchor Procedure

  1. Place unit into position to be mounted and cycle unit to set its stance.
  2. Wearing protective glasses, drill down into flooring perpendicularly to the required depth, ensuring that the foot thickness of the unit is being accounted for; refer to Anchor Selection and Foot Dimensions.
    Note: Use 3/8" size bit for Imperial anchors and 10mm for Metric anchors.
    Item Description Qty.
    1 Drill with Concrete Bit 1
    2 Upright 1
  3. Clear out debris from hole.
  4. Insert anchor assembly. Use hammer to tap dynamic anchors flush against upright's base plate.
    Note: This step only applies to dynamic anchors. Do not hammer static anchors.
    Item Description Qty.
    1 Hammer 1
    2 Anchor Assembly 1
    3 Base Plate 1
  5. Tighten to 30 foot-pounds for Imperial (45Nm for Metric), assuring there are at least 3 threads left exposed.
    Item Description Qty.
    1 Torque Wrench 1
    2 Anchor Assembly 1
  6. If necessary, cut extra length from top of anchor with a rotary tool leaving proper concrete engagement, torque requirements and at least 3 exposed threads.
    Item Description Qty.
    1 Rotary Tool 1
    2 Anchor Assembly 1
  7. Check anchors weekly and re-tighten to 30 Foot-Pounds for Imperial (45Nm for Metric) if needed. Failure to do so may jeopardize anchor effectiveness.