Electrical Power Requirements

Warning: Use only the supplied AC power line cord. Do not use any modification to connect to a 2-prong outlet. Product must be connected to a properly rated 3-prong outlet.

Symbio Upright Lifecycle Model: EVC

Supply Voltage Frequency Input Current
100 - 240 VAC 50 - 60 Hz 2.0 A
Outlet Voltage Commercial Units Outlet and Breaker (Amps) Consumer / Home Units Outlet and Breaker (Amps)
120 VAC 20 (no more than 6 cycles per breaker) 15 (no more than 4 cycles per breaker)
230 VAC 12 (no more than 6 cycles per breaker) 12 (no more than 4 cycles per breaker)

Symbio Upright SwitchCycle Model: EVCH

Supply Voltage Frequency Input Current
100 - 240 VAC 50 - 60 Hz 3.5 A
Outlet Voltage Commercial Units Outlet and Breaker (Amps) Consumer / Home Units Outlet and Breaker (Amps)
120 VAC 20 (no more than 4 cycles per breaker) 15 (no more than 3 cycles per breaker)
230 VAC 12 (no more than 4 cycles per breaker) 12 (no more than 3 cycles per breaker)
Note: Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet, have a proper outlet installed by a qualified electrician.
Note: Make sure the AC power line cord is securely connected to the base unit. A loose connection may result in the unit not receiving power.