Electrical Power Requirements
The treadmill requires a dedicated* line with isolated neutral according to the electrical configurations listed in the chart below.
| Supply Voltage (VAC) | Frequency (Hz) | Rated Current (Amps) |
|---|---|---|
| 100 | 50 / 60 | 18 |
| 120 | 50 / 60 | 18 |
| 200 | 50 / 60 | 9 |
| 220 | 50 / 60 | 9 |
| 230 | 50 / 60 | 9 |
| 240+ | 50 / 60 | 9 |
* One individual branch circuit for each treadmill per NEC article 210-21 (b) (1) and 210-22 (or other appropriate, country specific electrical compliance guidelines). The hot and neutral wires must each be routed independently (not looped or tied to other circuits).
Note: Do not modify the plug provided with this
product. If the plug does not fit into an available electrical outlet, have a proper
outlet installed by a qualified electrician.